German Indoor Extension Cord
-
Price:
Negotiable
- minimum:
- Total supply:
-
Delivery term:
The date of payment from buyers deliver within days
-
seat:
Zhejiang
-
Validity to:
Long-term effective
-
Last update:
2018-08-30 21:57
-
Browse the number:
297
+
- Contactaixin:
hongyigroup(Mr.)
- Email: telephone: phone:
-
Arrea:
Zhejiang
Address:East Area, Guan Haiwei Industrial Zone, Guan Haiwei CiXi, Ningbo, zhejiang China (Postcode: 315314)
-
Website:
http://www.hongyitechgroup.com/ http://hongyigroup.hq-huaqiao.com/
+
Germany type 16A 250V~, IP20, Class I, non-rewirable, single-way socket outlet complies with standard sheet CEE7/III,with shutter, with a non-rewirable plug, with cord H05VV-F 3G1,0-1,5mm 2 (max length be 2m for 1,0mm 2 and 30m for 1,5mm2 ).
Package: shrink + Label+ brown carton
PP materials .
Package: shrink + Label+ brown carton,
TUV/GS S CE ROHS PAHS REACH approval.
Summary of testing:
The test results comply with the requirements:
All clauses of IEC 60884-1:2002 (Third Edition) +A1:2006 + A2:2013 and IEC 60884-2-7:2011 +A1:2013.
DIN VDE 0620-2-1:2013 in conjunction with DIN VDE 0620-1:2013;
Appliances evaluated and complied with the PAK/PAH requirements of AfPS GS 2014:01 PAK.
The product fulfils the requirements of SS 4280834:2013, SFS 5610: 2015 +A11:2016 and NEK502:2016.
Warning:
1. Do not connect after each other
2. Do not cover when in use
3. To disconnect voltage pull the plug
4. For indoor use only
*Note: Only product with 3G1,5mm 2 cord can be used for Finland and Germany market.
16A 250V~, IP20, Class II, non-rewirable, with single way CEE 7/III socket-outlet with shutter, with a non-rewirable plug, with flexible cord H05VV-F (with or without fabric braided cover) 2G1,0-1,5mm 2 (Max. 2m for 1,0mm 2 in length and Max.30m for 1,5mm 2 ).
Package: shrink + Label+ brown carton
PP materials .
Package: shrink + Label+ brown carton,
KEMA CE ROHS PAHS REACH approval.
Summary of testing:
The test results comply with the requirements:
All clauses of IEC 60884-1:2002 (Third Edition) +A1:2006 + A2:2013 and IEC 60884-2-7:2011 +A1:2013.
The product fulfils the requirements of NEN 1020:1987+A2:2004
Warning:
1. Do not connect after each other
2. Do not cover when in use
3. To disconnect voltage pull the plug
4. For indoor use only
Germany type 16A 250V~, IP20, Class I, non-rewirable, with single way CEE 7/III socket-outlet with shutter,with a rotary switch, with a non-rewirable plug, with flexible cord H05VV-F (with or without fabric braided cover) 3G1,0-1,5mm 2 (Max. 2m for 1,0mm 2 in length and Max.30m for 1,5mm 2 ).
Package: shrink + Label+ brown carton
PP materials .
Package: shrink + Label+ brown carton,
TUV/GS S CE ROHS PAHS REACH approval.
Summary of testing:
The test results comply with the requirements:
All clauses of IEC 60884-1:2002 (Third Edition) +A1:2006 + A2:2013 and IEC 60884-2-7:2011 +A1:2013.
DIN VDE 0620-2-1:2013 in conjunction with DIN VDE 0620-1:2013;
Appliances evaluated and complied with the PAK/PAH requirements of AfPS GS 2014:01 PAK.
The product fulfils the requirements of SS 4280834:2013, SFS 5610: 2015 +A11:2016 and NEK502:2016.
Warning:
1. Do not connect after each other
2. Do not cover when in use
3. To disconnect voltage pull the plug
4. For indoor use only
*Note: Only product with 3G1,5mm 2 cord can be used for Finland and Germany market.
http://www.hongyitechgroup.com/